We buy surplus 138 kV cable
Most of Austin's bulk transmission runs at 138 kV. The cable for it appears in short underground dips, at substation exits, and on reels that a project bought and never pulled.

Send the lot
Six details are enough to start: what the cable is, how much there is, where it is and what condition it is in. Photos can follow by text or email.
Prefer to talk 954-740-1983At this voltage the cable is single conductor, heavily insulated and shielded, and it is bought in set lengths for a specific pull. That is why surplus tends to be whole. A reel either went into the duct and came back, or it never left the laydown at all, and the difference is the first thing a buyer asks about.
We review 138 kV reels on construction, length and sheath condition, with the paperwork read alongside. Photographs of the drum alone will not carry a review at this level. The tag, the cut end and the storage history decide whether a reel is reusable or recovery.
Reels that never left the laydown
A reel that was delivered to a project and never pulled is the best case in this class. The ends are capped, the lagging is intact, the tag matches the shipping papers, and the cable has not been bent beyond what the drum imposes. That reel can go back into a duct for another job.
Photograph it properly. The tag face, the drum stencilling, the end caps and the lagging, plus a tape across the flange. If the reel has been sitting outdoors through a summer, note the drum condition as well, because a drum that has started to spread is a loading problem before it is a cable problem.
Underground dips into downtown and campus substations
The 138 kV network goes underground where it has to: at substation exits, under the rail corridor, and along the streets that feed the downtown and university-area substations. Those dips are short, they are built in congested ground, and the cable for them is cut to a measured length with an allowance at each end.
When a dip is rebuilt, the removed cable comes out in the lengths it went in as, minus whatever the joints consumed. Removed cable at this voltage is reviewed with more caution than new surplus. Bending radius, sheath damage from the pull and water at the ends all count, and the review usually leans toward recovery.
Cut allowance, joints, and why a drum photo is not enough
Every joint and termination consumes cable. A project that needs four pulls will buy each length with an allowance, and the offcut comes back on a reel or is cut away on site. That allowance is why a reel can look substantial and still hold less usable length than the tag suggests.
So the review needs the tag, the measured length and the joint record. A photograph of a drum tells a buyer the flange is sound and the lagging is on. It cannot show a sheath that was nicked during a pull or an end that has been open since spring. Send the details, then let the site be seen.
What this page covers
The rows a buyer would fill in when reviewing this kind of lot. If your cable matches most of them, the submission is ready.
| Voltage class | 138 kV |
|---|---|
| Constructions reviewed | XLPE and EPR, lead sheath, copper wire shield |
| Typical conductor | 1,500 kcmil to 2,500 kcmil |
| Condition flags | Sheath damage, end caps removed, standing water |
| Site type | Transmission laydown, substation, duct bank staging |
From the downtown dips out to the SH-130 substations
The 138 kV ring reaches into the city core through duct banks under streets that were cut when the circuits went in, and out to the newer substations along SH-130 and SH-45. Each end of that ring has a laydown where reels wait, and each rebuild leaves material at one of them.
Campus and medical-district loads sit on the same network, so a project there can release cable that was bought for a tie which has since been reconfigured. Access downtown is the constraint: tell us the street, the loading window and whether a crane can set up before the review is scheduled.
Sellers ask
Can a 138 kV reel be reviewed from photographs alone?
Not to the point of a firm offer. Photographs establish the drum, the tag and the storage. The sheath, the cut ends and the joint record need to be seen or documented before a reel at this voltage can be judged reusable.
What is a cut allowance and why does it matter?
It is the extra length a project adds to each pull for joints and terminations. It is consumed on site, so the reel that comes back holds less than the length that was bought. The measured length, not the purchase figure, is what a review works from.
Do you take cable removed after years in a duct?
Yes, and it is reviewed as recovery more often than as reuse. Pulled cable carries bending marks, sheath scuffs and often water at the ends. Send the length, the construction and a picture of the ends, and the lot will be assessed on what it is.
What paperwork should travel with the reel?
The reel tag, the shipping or test documentation if it still exists, and a note on where and how long it was stored. Anything that shows the ends stayed sealed is worth more than a description of the jacket.
Send the reel list
Six details are enough to start: what the cable is, how much there is, where it is and what condition it is in. Photos can follow by text or email.
Prefer to talk 954-740-1983