Medium voltage cable: safety before handling
Cable that ran above a thousand volts does not become harmless when the breaker opens. It has to be proved dead, discharged and handled by people who know what they are holding.

Send the lot
Six details are enough to start: what the cable is, how much there is, where it is and what condition it is in. Photos can follow by text or email.
Prefer to talk 954-740-1983Medium voltage cable carries risks that building wire does not: stored charge, insulation damage that still looks sound, and terminations that stay dangerous long after the source is gone. A lot is not ready for review until the circuits feeding it are locked out and proved.
We buy medium voltage cable around Greater Austin, and we will not schedule a removal on an unproven circuit. The safety steps come before the paperwork, and the paperwork is what shows they happened, which is exactly what a buyer needs to see before a drum moves.
Lock out, prove dead, then cut
Every circuit needs a lock, a tag and a proved-dead check with a tester rated for the voltage, checked against a known source before and after. A breaker position is not proof. A label saying de-energised is not proof. Write the result down with a time and a name.
Cable cut while still connected to a remote source is the failure that hurts people. Confirm both ends, confirm the source is open, and confirm that no tie or transfer can backfeed the section before a saw goes anywhere near it.
Stored energy and damaged semicon
Long medium voltage cable holds charge like a capacitor, and it can hold it after the source is open. Discharge to ground with rated equipment, then prove dead again. Cables run in parallel hold more, and a section that reads dead at one end may not read dead at the other.
Damaged semicon is a handling hazard as well as a defect. A nick in the conductor screen concentrates stress, and exposed conductor at a cut end can be sharp, contaminated and awkward to move. Wear gloves, and use a reeler who has done it before.
Bend radius, dropped reels and supervision
Medium voltage cable has a minimum bend radius expressed as a multiple of its diameter, and going past it damages insulation from the inside where nobody sees it. Do not drop reels off a truck, do not roll them over a curb, and do not lift a drum with forks through the wraps.
Removal should have someone on site who is qualified for the voltage class and authorized to confirm the isolation. That is usually the utility's own crew, a qualified contractor, or both. A buyer arranging pickup is not a substitute for that person.
What this page covers
The rows a buyer would fill in when reviewing this kind of lot. If your cable matches most of them, the submission is ready.
| What we review | Isolation record, jacket and semicon condition |
|---|---|
| Typical lots | Padmount loops, feeder sections, gear tails |
| Voltage classes | 5 kV through 35 kV shielded cable |
| Condition accepted | Intact reels, cut sections, recovery |
| Documentation | Lockout record, voltage proof, photos |
| Before pickup | Circuit proved dead, ends sealed |
Medium voltage work around the Austin load
Medium voltage cable sits wherever the load is dense: padmount loops serving office and apartment sites, campus distribution at UT Austin and Texas State, hospital and data center feeders, and the utility primary that runs along most major corridors in Travis and Williamson counties.
Removals here usually follow a switchgear or padmount replacement, and the utility has a hand in the isolation. We work to that schedule across the region and take the lot once the circuit is confirmed dead and the record is in hand.
Sellers ask
The breaker is open. Can we start pulling?
Not yet. An open breaker is not a proved-dead circuit, and medium voltage cable can hold charge after the source is gone. Lock it out, test with rated equipment and discharge before anything is cut.
What does a damaged semicon look like?
A nick, a scrape or a ring of exposed conductor screen under the insulation, often where a reel was bent too tight or dropped. It can look minor and still be a defect. Photograph it and treat the reel as recovery.
Who should be there when the cable comes out?
Someone qualified for that voltage class and authorized to confirm the isolation, which is often the utility crew or a qualified contractor. They sign the isolation record and we schedule around their window.
Send the reel list