Surplus electrical cable and wire · Greater Austin and Central Texas

Austin TexasElectrical wire buyers
Cable category · we buy

We buy surplus USE-2 cable

A long single length of USE-2 is a different asset from the same footage in cut pieces. Tell us the reel, the size and the run it was bought for.

  • 600 V
  • USE-2, RHW-2/USE-2 dual rated
  • 14 AWG to 500 kcmil
Two people standing among wooden and steel cable reels in a gravel storage yard
Buying desk · USE-2 cable, Greater Austin

Send the lot

Six details are enough to start: what the cable is, how much there is, where it is and what condition it is in. Photos can follow by text or email.

Prefer to talk 954-740-1983

saleselectricalbuyers@gmail.com

No fee and no obligation. A buyer reviews the lot from these details. Nothing moves until written lot terms are agreed.

USE-2 arrives from rural service work, well and pump installs, and solar jobs where the conductor is direct buried. We take it in copper and aluminum, 2 AWG through 4/0, single conductor and the dual-rated RHW-2/USE-2 constructions that carry both markings on the same jacket.

Most lots are one or two reels with a few hundred feet left, plus a coil or two in the truck box. Because the material is direct burial rated, the jacket is heavier than building wire and survives storage better. The review still turns on length, since continuous runs are what another crew wants.

The dual rating stamped on the jacket

USE-2 is a single-conductor direct-burial cable. Much of what we see is also marked RHW-2, which means the same jacket carries a second rating and can be used in wet locations above ground as well. Both markings are read from the print on the jacket, not from the reel tag.

Copper and aluminum both come through. Aluminum from 2 AWG to 4/0 turns up on long rural service runs where the distance is great. Copper shows up on pump work, on solar DC and on short services where the installer wanted a smaller conductor for the same load.

One long length against the same footage in pieces

Cut USE-2 into twenty-foot pieces and it becomes recovery material. Left on the reel as a continuous run of several hundred feet, it can go to another crew for a service or a well drop. That is the difference the review looks for, and it is why we ask for the tag first.

Where a length has been cut we still want the pieces listed by size. A fifty-foot tail is worth handling if there are ten of them in the same size. The lot is added up by size and metal, then read against what a continuous length of the same size would do.

Reel tags, county roads and a truck that fits

Photograph the tag, the jacket print near the end, and the whole reel from the side. Note whether the cable was buried and pulled back out, because a jacket scuffed by rock and backfill is a different review from one that never left the reel.

Access matters on rural lots. Tell us the gate width, whether a trailer can turn around, and whether the reel sits on a slab or in grass. The pickup is set after terms are agreed, and a winch truck or a flatbed is chosen for the ground it has to cross.

At a glance

What this page covers

The rows a buyer would fill in when reviewing this kind of lot. If your cable matches most of them, the submission is ready.

Lot review sheet
Voltage rating600 V
RatingsUSE-2, RHW-2/USE-2 dual rated
Sizes reviewed14 AWG to 500 kcmil
Condition acceptedNew surplus, partial reel, removed
Site typeRural service, solar, agricultural
Local notes

Rural service work from Dripping Springs to Bastrop

Long driveways and well drops are the norm west of Austin, where Hays and Burnet county properties sit off the county roads and the meter can be several hundred feet from the house. That work uses USE-2 in lengths that rarely come back to a warehouse shelf.

East of the city the pattern changes. Bastrop and Caldwell county service work, poultry and cattle operations, and the solar arrays going in along US-290 and SH-71 all leave partial reels behind. We cover both sides of the metro and the open country between them.

Questions

Sellers ask

Can you take a reel with only a hundred feet left?

Yes. Short lengths are common in service work, and a hundred feet of 4/0 aluminum still has a use for a well drop or a shed service. It will be read as a short length rather than a full reel, and that changes how the lot is reviewed.

Does the jacket print matter if the tag is missing?

It helps a great deal. The print tells us the rating, the size, and often the maker and the year. Photograph it close to the cut end, where it is usually clearest, and the cable can be identified without the tag.

Do you take cable that has been buried?

We do, with the caveat that a buried and recovered jacket is inspected closely for rock damage and water at the ends. Say how long it was in the ground and send a photograph of the end cut square, so the conductor and insulation are visible.

Buying desk · USE-2 cable, Greater Austin

Send the reel list

Six details are enough to start: what the cable is, how much there is, where it is and what condition it is in. Photos can follow by text or email.

Prefer to talk 954-740-1983

saleselectricalbuyers@gmail.com

No fee and no obligation. A buyer reviews the lot from these details. Nothing moves until written lot terms are agreed.

Call 954-740-1983 Request a Quote