We buy surplus fiber optic cable
Strand count, construction and documentation decide a fiber reel. An intact, tested reel is a different asset from a coil of cut cable.

Send the lot
Six details are enough to start: what the cable is, how much there is, where it is and what condition it is in. Photos can follow by text or email.
Prefer to talk 954-740-1983Fiber is read on the reel, not on the glass. Reels arrive as single-mode or multimode, loose tube outside plant or tight buffer inside plant, in plenum and riser constructions, from 2 strands up to 144. OS2, OM3 and OM4 are the types that come through most often.
The value here sits in the reel, not the glass. Glass is cheap and splicing is not, so an intact reel with test data and a readable length can go straight to another route, while cut fiber becomes a small recovery item. That distinction drives the whole review.
Single-mode, multimode and strand count
Single-mode cable carries one path and is used for distance. Multimode carries several and is used within buildings and campuses. OM3 and OM4 are the grades that appear on current work, with OS2 on anything leaving a building or crossing a site.
Strand count runs from 2 up to 144 on the reels we see, and it is printed on the jacket along with the type. A 144-strand reel and a 12-strand reel are the same size drum but not the same item, so the count is recorded first.
Loose tube outside plant against tight buffer inside plant
Loose tube cable puts each fiber in a gel-filled tube inside the jacket, which protects it from moisture and from the movement that comes with outdoor installation. Tight buffer cable puts a coating directly on the fiber and is used indoors, where it can be connectorized easily.
Plenum and riser versions of the indoor cable carry the same logic as copper: the jacket compound is chosen for where it runs. We list construction as part of the description, because an outside plant reel will not substitute for a plenum run in a return air space.
Intact reels, test data and cut fiber
A reel that has never been unspooled, with the factory length and the test sheet, is the best case. Test data matters because it proves attenuation before the cable was handled, and a route owner will ask for it. Without the sheet the reel is still bought, but read with less confidence.
Cut fiber has limited recovery value because the glass itself is not worth much and a splice takes a technician and a fusion set. A short cut length with connectors on both ends is a jumper and is read differently. Say which you have, since a coil of cut fiber and a box of jumpers are not the same lot.
What this page covers
The rows a buyer would fill in when reviewing this kind of lot. If your cable matches most of them, the submission is ready.
| Types | OS2 single-mode, OM3 and OM4 multimode |
|---|---|
| Constructions | Loose tube OSP, tight buffer, plenum |
| Strand counts | 2 to 144 |
| Condition flags | Cut, unspooled, missing test data |
| Site type | Telecom, campus, data center |
Campus and carrier routes across the metro
Fiber in this region moves with the carriers and the campuses. Utility and telecom duct banks run along I-35, MoPac and the SH-130 corridor, and a route change leaves reels in a laydown that were cut for the original path. Those reels are usually long and well documented.
Institutional work at UT Austin, Texas State in San Marcos and the school districts across Williamson and Hays counties produces indoor reels and jumpers. A campus rewire leaves a dozen part reels and a box of patch cables. Data center builds along SH-71 add plenum reels in quantity, often still sealed and tagged.
Sellers ask
Does fiber need test data to be bought?
It is not required, but it changes the review. A reel with the factory test sheet and the length marked is read with more confidence than one without. Where the sheet is gone, the jacket print and the reel label still identify the cable and its length.
Is cut fiber worth anything?
Very little on its own, because the glass has almost no recovery value and a splice takes a technician and a fusion set. A cut length with connectors on both ends is a jumper and is read as one. Keep jumpers apart from loose cut fiber.
Can a reel that has been unspooled be sold on?
It can, but it is read as a partial reel with handling behind it. Note how much was used and whether the remaining end was sealed and capped. A reel with an open, unsealed end and no length marked is the hardest case to place.
Send the reel list
Six details are enough to start: what the cable is, how much there is, where it is and what condition it is in. Photos can follow by text or email.
Prefer to talk 954-740-1983